Solution: Battery simulation and grid simulation
Solution: Battery simulation and grid simulation
Battery simulation and grid simulation
Accreditation
Battery simulation and grid simulation
The energy transition is bringing ever further electrification of products. In this context, compliance with specifications in a common power grid is of central importance. With the help of grid and battery simulators, products can be tested and optimized in a wide range of grid conditions and load cases.
The application areas of these simulations are wide-ranging and extend from railway and aviation to mobility or e-vehicles incl. charging infrastructure to electromagnetic compatibility or electrical safety. These simulations are also used in drive technology, but also for photovoltaics, heat pumps and in environmental simulation.
Grid simulation – performance data (AC voltage sources)
TÜV AUSTRIA can perform simulations with AC voltage in the following extent:
- 8xRegatron ACS (50kVA each), i.e. up to 400kVA;
- 4-quadrant network simulation, divisible into 2 blocks (2x200kVA).
- Voltage ranges from 0 – 1000 Vac,
- Frequency range 16-800Hz (16Hz railroad grid, 50Hz power grid Europe, 60Hz power grid USA/Canada, 400hz & 800Hz Aviation),
- Continuous current 576A (max. 1.152A).
Battery simulation – performance data (DC voltage sources)
TÜV AUSTRIA can perform simulations with DC voltage in the following extent:
- 7x Regatron G5 (54kW each), i.e. 378kW,
- divisible into 2 blocks (216kW + 162kW);
- Voltage range 0 – 1.500Vdc,
- Current 756A.
Application areas of battery simulation and grid simulation
These voltage sources can be used by our experts from TÜV AUSTRIA in different laboratory areas:
- Via appropriate filtering devices in the EMC hall.
- In the e-testing area, e.g. in connection with our e-mobility testing equipment.
- In the climate chamber, also in connection with the e-mobility test facility.